Threaded Penetration Fittings |
|
DPM’s threaded penetrations are constructed of an Acetal body and nut. The boot is Alcryn. They ship complete with 300 series stainless steel band clamps. DPM’s threaded penetrations have the threads machined in lieu of molding. This assures a consistent match fit between the components. |
|
Diversified Products Manufacturing, Inc. |
|
To contact us: |



|
B2 |
|
B3.5 |
|
B3.5 |
|
With Reducer |
|
B3.5 |
|
With Reducer and Air Valve |
|
B5 |
|
B5 |
|
With Reducer |
|
B5 |
|
With Reducer and Air Valve |
|
B5CD |
|
B6 |
|
B6 |
|
With Reducer |
|
B6 |
|
With Reducer and Air Valve |
|
5523 Baggett-Marysville Rd |
|
Oroville, Ca 95965 |
|
Phone: 530.534.3966 |
|
Fax: 530.534.7404 |
|
www.dpm-llc.com |
Home |
About Us |
Products |
Literature |
Certified Installers |
What’s New |
Employment |
Contact Us |
|
Standard |
Metric |
Application |
|
B2-1.1 |
|
for Pipe with OD sizes 1.0 to 1.1" Typically 3/4" Rigid Conduit |
|
B2-1.2 |
|
for Pipe with OD sizes 1.1 to 1.2" Typically 3/4" PVC Coated Rigid Conduit |
|
B2-1.3 |
B2-32 |
for Pipe with OD sizes 1.2 to 1.3" Typically 32 mm Pipe |
|
B2-1.4 |
|
for Pipe with OD sizes 1.3 to 1.4" Typically 1" or 1" PVC Coated Rigid Conduit |
|
B2-41 |
|
for Pipe with OD sizes 1.3 to 1.4" w/ Insert Typically for 3/4" & 1" Rigid Conduits |
|
Standard |
Metric |
Application |
|
B3.5-1.5 |
|
for Pipe with OD sizes 1.3 to 1.5" |
|
B3.5-1.6 |
B3.5-40 |
for Pipe with OD sizes 1.5 to 1.6" typically 40 mm Pipe |
|
B3.5-1.7 |
|
for Pipe with OD sizes 1.6 to 1.7" typically 1 1/4" nominal Pipe |
|
B3.5-1.9 |
|
for Pipe with OD sizes 1.7 to 1.9" typically 1 1/2" nominal Pipe |
|
B3.5-2.0 |
B3.5-50 |
for Pipe with OD sizes 1.9 to 2.0" typically 1 1/2" OPW flex Pipe & 50 mm pipe |
|
B3.5-2.1 |
|
for Pipe with OD sizes 2.0 to 2.1" typically |
|
B3.5-2.2 |
B3.5-54 |
for Pipe with OD sizes 2.1 to 2.2" typically 54 mm Pipe |
|
B3.5-2.4 |
|
for Pipe with OD sizes 2.2 to 2.4" typically 2" Fiberglass or Steel Pipe |
|
B3.5-2.5 |
B3.5-63 |
for Pipe with OD sizes 2.4 to 2.5" typically 63 MM Pipe |
|
B3.5-2.7 |
|
for Pipe with OD sizes 2.5 to 2.7" typically Ameron 2" LCX Pipe |
|
Standard |
Metric |
Application |
|
B3.5-1.6x1.3 |
B3.5- 40x32 |
for pipe with 40mm Secondary with 32 mm Primary |
|
B3.5-2.5x2.0 |
B3.5- 63x50 |
for pipe with 63mm Secondary with 50mm Primary |
|
B3.5-2.7x2.4 |
|
for Ameron 2" LCX pipe |
|
Standard |
Metric |
Application |
|
B3.5-1.6x1.3A |
B3.5- 40x32A |
for pipe with 40mm Secondary with 32 mm Primary |
|
B3.5-2.5x2.0A |
B3.5- 63x50A |
for pipe with 63mm Secondary with 50mm Primary |
|
B3.5-2.7x2.4A |
|
for Ameron 2" LCX pipe |
|
Standard |
Metric |
Application |
|
B5-2.7 |
|
for Pipe with OD sizes 2.5 to 2.7" typically Ameron 2" LCX Pipe |
|
B5-3.0 |
B5-75 |
for Pipe with OD sizes 2.9 to 3.0" typically 75 mm Pipe |
|
B5-3.6 |
B5-90 |
for Pipe with OD sizes 3.5 to 3.6" typically 3" nominal or 75mm Pipe |
|
B5-3.8 |
|
for Pipe with OD sizes 3.7 to 3.8" typically Ameron 3" LCX Pipe |
|
Standard |
Metric |
Application |
|
B5-3.0x2.5 |
B5-75x63 |
for Pipe with 75mm Secondary with 63 mm Primary |
|
B5-3.6x2.4 |
|
for Pipe with 3" Secondary with 2" primary typically 3" over 2" FRP |
|
B5-3.6x3.0 |
B5-90x75 |
for Pipe with 90mm secondary with 75mm primary |
|
B5-3.8x3.6 |
|
for Pipe with 3.8" Secondary with 3.5" Primary Typically Ameron 3" LCX |
|
Standard |
Metric |
Application |
|
B5-3.0x2.5A |
B5-75x63A |
for Pipe with 75mm Secondary with 63 mm Primary |
|
B5-3.6x2.4A |
|
for Pipe with 3" Secondary with 2" primary typically 3" over 2" FRP |
|
B5-3.6x3.0A |
B5-90x75A |
for Pipe with 90mm secondary with 75mm primary |
|
B5-3.8x3.6A |
|
for Pipe with 3.8" Secondary with 3.5" Primary Typically Ameron 3" LCX |
|
Optional Corrugated Duct Connection |
|
This fitting may be used to seal to 4" Nominal corrugated Ducting. Add A C to the B5 product number ato create |
|
a B5CD-x.x, B5CD-x.xXx.x, or B5CD-x.xXx.xA. The optional corrugated ducting feature includes an additional band clamp |
|
water tight securing the corrugated ducting to the external sump wall. |
|
|
|
The price adder may be used for penetrations with integral reducers and integral reducers with air test valves. |
|
Standard |
Metric |
Application |
|
B6-3.8 |
|
for Pipe with OD sizes 3.7 to 3.8" typically Ameron 3" LCX |
|
B6-4.4 |
B6-110 |
for Pipe with OD sizes 4.3 to 4.4" typically 110 mm Pipe |
|
B6-4.5 |
|
for Pipe with OD sizes 4.4 to 4.5" typically 4" nominal Pipe |
|
B6-4.8 |
|
for Pipe with OD sizes 4.7 to 4.8" typically 4" Ameron LCX Pipe |
|
B6-5.0 |
B6-125 |
for Pipe with OD sizes 4.9 to 5.0" typically 125mm Pipe |
|
Standard |
Metric |
Application |
|
B6-3.8x3.5 |
|
for Pipe with 3.8" secondary with 3.5" Primary typically 3" LCX |
|
B6-4.4x3.6 |
B6-110x90 |
for Pipe with 110mm secondary with 90mm Primary |
|
B6-4.5x3.6 |
|
for Pipe with 4.5" Secondary with 3.5" Primary typically 4 over 3 FRP |
|
B6-4.8x4.5 |
|
for Pipe with 4.8" Secondary with 4.5" Primary typically Ameron 4" LCX pipe |
|
B6-5.0x4.4 |
B6-125x110 |
for Pipe with OD sizes 4.9 to 5.0" typically 125mm Pipe |
|
Standard |
Metric |
Application |
|
B6-3.8x3.5A |
|
for Pipe with 3.8" secondary with 3.5" Primary typically 3" LCX |
|
B6-4.4x3.6A |
B6-110x90A |
for Pipe with 110mm secondary with 90mm Primary |
|
B6-4.5x3.6A |
|
for Pipe with 4.5" Secondary with 3.5" Primary typically 4 over 3 FRP |
|
B6-4.8x4.5A |
|
for Pipe with 4.8" Secondary with 4.5" Primary typically Ameron 4" LCX pipe |
|
B6-5.0x4.4A |
B6-125x110A |
for Pipe with OD sizes 4.9 to 5.0" typically 125mm Pipe |